1.
PLoS One ; 16(8): e0256469, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1372013

RESUMEN

The current COVID-19 pandemic has led the world to an unprecedented global shortage of ventilators, and its sharing has been proposed as an alternative to meet the surge. This study outlines the performance of a preformed novel interface called 'ACRA', designed to split ventilator outflow into two breathing systems. The 'ACRA' interface was built using medical use approved components. It consists of four unidirectional valves, two adjustable flow-restrictor valves placed on the inspiratory limbs of each unit, and one adjustable PEEP valve placed on the expiratory limb of the unit that would require a greater PEEP. The interface was interposed between a ventilator and two lung units (phase I), two breathing simulators (phase II) and two live pigs with heterogeneous lung conditions (phase III). The interface and ventilator adjustments tested the ability to regulate individual pressures and the resulting tidal volumes. Data were analyzed using Friedman and Wilcoxon tests test (p < 0.05). Ventilator outflow splitting, independent pressure adjustments and individual tidal volume monitoring were feasible in all phases. In all experimental measurements, dual ventilation allowed for individual and tight adjustments of the pressure, and thus volume delivered to each paired lung unit without affecting the other unit's ventilation-all the modifications performed on the ventilator equally affected both paired lung units. Although only suggested during a dire crisis, this experiment supports dual ventilation as an alternative worth to be considered.


Asunto(s)
Pulmón/fisiopatología , Síndrome de Dificultad Respiratoria/fisiopatología , Ventiladores Mecánicos , Animales , Presión Sanguínea , Dióxido de Carbono/química , Simulación por Computador , Modelos Animales de Enfermedad , Frecuencia Cardíaca , Concentración de Iones de Hidrógeno , Porcinos , Volumen de Ventilación Pulmonar
2.
PLoS One ; 16(5): e0250672, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1256035

RESUMEN

In this work a shared pressure-controlled ventilation device for two patients is considered. By the use of different valves incorporated to the circuit, the device enables the restriction of possible cross contamination and the individualization of tidal volumes, driving pressures, and positive end expiratory pressure PEEP. Possible interactions in the expiratory dynamics of different pairs of patients are evaluated in terms of the characteristic exhalatory times. These characteristic times can not be easily established using simple linear lumped element models. For this purpose, a 1D model using the Hydraulic and Mechanical libraries in Matlab Simulink was developed. In this sense, experiments accompany this study to validate the model and characterize the different valves of the circuit. Our results show that connecting two patients in parallel to a ventilator always resulted in delays of time during the exhalation. The size of this effect depends on different parameters associated with the patients, the circuit and the ventilator. The dynamics of the exhalation of both patients is determined by the ratios between patients exhalatory resistances, compliances, driving pressures and PEEPs. Adverse effects on exhalations became less noticeable when respiratory parameters of both patients were similar, flow resistances of valves added to the circuit were negligible, and when the ventilator exhalatory valve resistance was also negligible. The asymmetries of driving pressures, compliances or resistances exacerbated the possibility of auto-PEEP and the increase in relaxation times became greater in one patient than in the other. In contrast, exhalatory dynamics were less sensitive to the ratio of PEEP imposed to the patients.


Asunto(s)
Espiración , Respiración Artificial/instrumentación , Ventiladores Mecánicos , Humanos